Limotec, reliable detection of fire, gas and co

with certificats

Limotec MD2400SA - 2 loop fire alarm control panel

The MD2400SA, analogue addressable fire detection and fire warning control panel for buildings, has been designed in accordance with European Standards EN54-2:1997/A1:2006 and EN54-4:1997/A1:2002/A2:2006.

The BOSEC EN54-13 certification in combination with the SOTERIA range of detectors is pending.

The MD2400SA fire alarm control panel has a maximum capacity of 2 loops. Communication with the connected fire detectors and alarm devices is based on the CoreProtocol®.

Limotec MD300 - 16-zone fire alarm control panel

The MD300, a 16-zone conventional fire detection and fire warning control panel for buildings, has been designed in accordance with European Standards EN54-2:1997/A1:2006 and EN54-4:1997/A1:2002/A2:2006 and is covered by the EC-Certificate of Conformity 1134-CPD-113.

The MD300 fire alarm control panel is BOSEC certified in combination with the Apollo Series 65 optical smoke detector (B-9072-FD-904), the Apollo Series 65 heat A1R detector (B-9072-FD-905) and the Apollo ORBIS multisensor detector (B-9072-FD-906).

Limotec MD2400L - 3 loop fire alarm control panel

The MD2400L, analogue addressable fire detection and fire warning control panel for buildings, has been designed in accordance with European Standards EN54-2:1997/A1:2006 and EN54-4:1997/A1:2002/A2:2006 and is covered by the EC-Certificate of Conformity 1134-CPD-077. The MD2400L fire detection system is BOSEC B-9072-FD-954 EN54-13 certified.

The MD2400L fire alarm control panel has a maximum capacity of 3 loops. Communication with the connected fire detectors and alarm devices is based on the XP95 digital protocol.

Limotec MD2400 - 16 loop fire alarm control panel

The MD2400, analogue addressable fire detection and fire warning control panel for buildings, has been designed in accordance with European Standards EN54-2:1997/A1:2006 and EN54-4:1997/A1:2002/A2:2006 and is covered by the EC-Certificate of Conformity 1134-CPD-077. The MD2400 fire detection system is BOSEC B-9072-FD-954 EN54-13 certified.

The MD2400 fire alarm control panel is composed of a central processing unit (black-box) and at least one operator console. The MD2400 control panel has a maximum capacity of 16 loops. Communication with the connected fire detectors and alarm devices is based on the XP95 digital protocol.

Limotec MD644 - 4-zone fire alarm control panel

The MD644, a 4-zone conventional fire detection and fire warning control panel for buildings, has been designed in accordance with European Standards EN54-2:1997/A1:2006 and EN54-4:1997/A1:2002/A2:2006 and is covered by the EC-Certificate of Conformity 1134-CPD-106.

The MD644 fire alarm control panel is BOSEC certified in combination with the Apollo Series 65 optical smoke detector (B-9072-FD-897), the Apollo Series 65 heat A1R detector (B-9072-FD-898) and the Apollo ORBIS multisensor detector (B-9072-FD-899).

Limotec MD780 - Gas & CO detection system

The MD780 gas & CO detection system is appropriate for connecting up to 8 external gas and/or CO detectors.

The functioning of the MD780 gas sensors is based on the principle of catalytic combustion. The MD780 gas sensor can be used for the detection of methane, propane or butane. The MD780 gas detector is available in a non-explosion proof housing and in an ISSeP15ATEX0030 certified housing.

The MD780 CO sensor operates on the fuel cell principle and is appropriate for the detection of carbon monoxide gas.

General information & communications

In view of the current situation and the measures imposed by the government, Limotec is taking the necessary precautions to help combat the spread of the Corona virus. Until further notice, all our internal services remain accessible and available.

The delivery of ordered materials is still guaranteed for the time being. However, the current situation may lead to delays in the production process and in the supply of peripheral equipment. The situation is continuously monitored and any changes will be communicated immediately.

All planned training courses will be cancelled for the time being and moved to a later date.

Requests for interventions by our technical department are assessed individually and planned in function of urgency. An urgent intervention will only be carried out under the condition that the government measures are complied with and that the social distancing guidelines are respected. All non-urgent interventions will be postponed to a later date in consulation with the applicant.

Limotec takes all necessary steps to guarantee the continuity of our services.

We thank everyone for understanding in these difficult circumstances and hope to be able to return to normal life soon!

 

Due to stock taking and the implementation of a new ERP system, no deliveries of materials can take place from Mondag 30 March to Friday 3 April 2020.

Vacancies

FIELD ENGINEER FOR IMMEDIATE RECRUITMENT

Click here