Linear smoke detectors - OSID 

OSID 
- Linear smoke detectors -

More info

OSID 
- Options -

More info

TheFireBeam 
- Linear smoke detectors -

More info

TheFireBeam 
- Options -

More info


|| Linear smoke detectors - OSID ||


OSID – receiver 7° with standard transmitter 24Vdc


  • Range without IP66 enclosure : 30 to 150 metres 
  • Supply voltage: 20 – 30Vdc (nominal 24Vdc)
  • Sensitivity adjustable to 20%, 35% or 50% beam obscuration
  • Current consumption receiver: 8mA@24Vdc
  • Current consumption transmitter: 350µA@24Vdc 

  | 

SUITABLE FOR :  |  MD2400SA  |  MD2400L  |  MD2400  |

EN54-13 CERTIFICATE :  MD2400/MD2400L : B-9072-FD-1049

STOCK KEEPING ARTICLE

TOP

 Downloads 


Datasheet  |  NL  |  FR  |

Cert. of Constancy of Performance  |  EN  |

Declaration of Performance  |  EN  |

BOSEC Certificate  |  NL  |  FR  |  EN  |

 Info for the installer

Wiring diagram  | NL  |  FR  |

Installation manual  | NL  |  FR  |  EN  |

OSID – receiver 7° with high power transmitter 24Vdc


  • Range without IP66 enclosure : 100 to 200 metres 
  • Supply voltage: 20 – 30Vdc (nominal 24Vdc)
  • Sensitivity adjustable to 20%, 35% or 50% beam obscuration
  • Current consumption receiver: 8mA@24Vdc
  • Current consumption transmitter: 800µA@24Vdc 

  | 

SUITABLE FOR :  |  MD2400SA  |  MD2400L  |  MD2400  |

EN54-13 CERTIFICATE :  MD2400/MD2400L : B-9072-FD-1049

STOCK KEEPING ARTICLE

TOP

 Downloads


Datasheet  |  NL  |  FR  |

Cert. of Constancy of Performance  |  EN  |

Declaration of Performance  |  EN  |

BOSEC Certificate  |  NL  |  FR  |  EN  |

 Info for the installer

Wiring diagram  | NL  |  FR  |

Installation manual  | NL  |  FR  |  EN  |

OSID – receiver 80° with standard transmitter 24Vdc


  • Range without IP66 enclosure : 6 to 34 metres 
  • Supply voltage: 20 – 30Vdc (nominal 24Vdc)
  • Sensitivity adjustable to 20%, 35% or 50% beam obscuration
  • Current consumption receiver with 1 transmitter: 8mA@24Vdc
  • Current consumption receiver with 7 transmitters: 10mA@24Vdc
  • Current consumption transmitter: 350µA@24Vdc 

  | 

SUITABLE FOR :  |  MD2400SA  |  MD2400L  |  MD2400  |

EN54-13 CERTIFICATE :  MD2400/MD2400L : B-9072-FD-1049

ON ORDER

TOP

 Downloads


Datasheet  |  NL  |  FR  |

Cert. of Constancy of Performance  |  EN  |

Declaration of Performance  |  EN  |

BOSEC Certificate  |  NL  |  FR  |  EN  |

 Info for the installer

Wiring diagram  | NL  |  FR  |

Installation manual  | NL  |  FR  |  EN  |

OSID – receiver 80° with high power transmitter 24Vdc


  • Range without IP66 enclosure : 12 to 68 metres 
  • Supply voltage: 20 – 30Vdc (nominal 24Vdc)
  • Sensitivity adjustable to 20%, 35% or 50% beam obscuration
  • Current consumption receiver with 1 transmitter: 8mA@24Vdc
  • Current consumption receiver with 7 transmitters: 10mA@24Vdc
  • Current consumption transmitter: 800µA@24Vdc 

  | 

SUITABLE FOR :  |  MD2400SA  |  MD2400L  |  MD2400  |

EN54-13 CERTIFICATE :  MD2400/MD2400L : B-9072-FD-1049

ON ORDER

TOP

 Downloads


Datasheet  |  NL  |  FR  |

Cert. of Constancy of Performance  |  EN  |

Declaration of Performance  |  EN  |

BOSEC Certificate  |  NL  |  FR  |  EN  |

 Info for the installer

Wiring diagram  | NL  |  FR  |

Installation manual  | NL  |  FR  |  EN  |


|| Options for OSID ||


OSID – IP66 enclosure for emitter 
- Art. OS-IEHE -


  • IP66 enclosure for use in harsh environments 
  • Protects against dust and water
  • Entry and exit opening for wiring


  

STOCK KEEPING ARTICLE

TOP

 Downloads OS-IEHE


Datasheet  |  NL  |  FR  |

OSID – IP66 enclosure for receiver 
- Art. OS-IEHI -


  • IP66 enclosure for use in harsh environments 
  • Protects against dust and water
  • Entry and exit opening for wiring
  • Range 7° receiver with IP66 enclosure: 25 to 125 meter
  • Range 80° receiver with IP66 enclosure: 5 to 28 meter
        | 

STOCK KEEPING ARTICLE

TOP

 Downloads OS-IEHI


Datasheet  |  NL  |  FR  |


|| TheFireBeam - Linear smoke detectors ||


TheFireBeam – Reflective linear smoke detector up to 70 metres
- Art. TFB-FB40 -


  • ​Standard range from 7 to 70 metres
  • Commissioning, adjustment and maintenance from controller at ground level
  • Remains automatically aligned during building movements
  • Using the optional reflector kit TFB-140/160KIT, distances between 140 and 160 metres can be covered
  • Reliable detection to provide cost-effective solutions for protecting large open areas


ON ORDER

TOP

 Downloads TFB-FB40


Datasheet  |  NL  |  FR  |  EN  |

Cert. of Constancy of Performance  |  EN  |

Declaration of Performance  |  EN  |

 Info for the installer

Wiring diagram  |  EN  |

User guide   |  EN  |

TheFireBeam – Reflective linear smoke detector up to 70 metres – Bluetooth
- Art. TFB-FBBLUE -


  • ​Standard range from 7 to 70 metres
  • Readout and alignment is done by Bluetooth connection  
  • Remains automatically aligned during building movements
  • Using the optional reflector kit TFB-140/160KIT, distances between 140 and 160 metres can be covered
  • Reliable detection to provide cost-effective solutions for protecting large open areas


ON ORDER

TOP

 Downloads TFB-FBBLUE


Datasheet  |  NL  |  FR   |

Cert. of Constancy of Performance  |  EN  |

Declaration of Performance  |  EN  |


|| TheFireBeam - Options ||


TheFireBeam – Reflector kit for distances from 70 to 140 metres
- Art. TFB-70/140KIT -


  • ​Reflector size determines the distance the linear smoke detector can cover
  • The optional reflector kit TFB-70/140KIT allows covering distances between 70 and 140 metres
  • Consists of a clear acrylic plate with 3 additional reflectors
  • The reflector supplied as standard must be added to the free space
  • Dimensions acrylic plate (H x W): 293 x 293mm



ON ORDER

TOP

 Downloads TFB-70/140KIT


Datasheet  |  NL  |  FR   |

TheFireBeam – Reflector kit for distances from 140 to 160 metres 
- Art. TFB-140/160KIT -


  • ​Reflector size determines the distance the linear smoke detector can cover
  • The optional reflector kit TFB-140/160KIT allows covering distances between 140 and 160 metres
  • Consists of a clear acrylic plate with 8 additional reflectors
  • The reflector supplied as standard must be added to the free space
  • Dimensions acrylic plate (H x W): 394 x 394mm 



ON ORDER

TOP

 Downloads TFB-140/160KIT


Datasheet  |  NL  |  FR   |

TheFireBeam – Kit anti-condensation for linear smoke detector TFB-FB40
- Art. TFB-AFS -


  • Kit specially designed to prevent condensation problems
  • Contains a reflector and a lens cover
  • Both are treated with a special Nano technology finish that prevents condensation
  • The anti-condensation kit prevents the possibility of false alarms in high condensation environments


ON ORDER

TOP

 Downloads TFB-AFS


Datasheet  |  NL  |  FR   |