|| XP95 detectors ||
XP95 optical smoke detector - Art. 085003 -
- Optical smoke detector without base
- Detection principle : scattered light
- Supply voltage : 17 - 28Vdc
- Quiescent current : 340µA
- Supply Wiring : Two wire supply, polarity insensitive
EN54-13 CERTIFICATE : MD2400/MD2400L : B-9072-FD-954
STOCK KEEPING ARTICLE
XP95 multisensor detector - Art. 085801 -
- Multisensor detector without base
- Detection principle : smoke: scattered light - heat: temperature-sensitive resistance
- Supply voltage : 17 - 28Vdc
- Quiescent current : 500µA
- Supply Wiring : Two wire supply, polarity insensitive
EN54-13 CERTIFICATE : MD2400/MD2400L : B-9072-FD-954
STOCK KEEPING ARTICLE
XP95 heat detector 55°C (A2S)
- Art. 085004 -
- Heat detector 55°C (A2S) without base
- Detection principle : single NTC thermistor
- Supply voltage : 17 - 28Vdc
- Quiescent current : 300µA
- Supply Wiring : Two wire supply, polarity insensitive
EN54-13 CERTIFICATE : MD2400/MD2400L : B-9072-FD-954
STOCK KEEPING ARTICLE
XP95 heat detector 90°C (CS)
- Art. 085005 -
- Heat detector 90°C (CS) without base
- Detection principle : single NTC thermistor
- Supply voltage : 17 - 28Vdc
- Quiescent current : 300µA
- Supply Wiring : Two wire supply, polarity insensitive
EN54-13 CERTIFICATE : MD2400/MD2400L : B-9072-FD-954
STOCK KEEPING ARTICLE
|| Bases for XP95 detectors ||
XPERT 7 base — heated - Art. 085011 -
- XPERT 7 base — heated
- For use in cold environments in combination with a deckhead mounting box (Art. 900939A)
- Supply voltage : 24Vdc
- Current consumption : 125mA@24Vdc
- Supply wiring : 4 wire supply, polarity sensitive
STOCK KEEPING ARTICLE
Discovery Sounder Base – DIN tone - Isolating - Art. 085409 -
- Base for XP95 detector with built-in sounder and isolator
- Supply voltage : 17 – 28Vdc
- Quiescent current consumption: 200µA@24Vdc
- Current consumption sounder operating: 5mA@24Vdc
- Sounder output high volume setting: 65 – 84db(A) (complies with EN54-3)
- Sounder output low volume setting: 50 to 65dB(A)
STOCK KEEPING ARTICLE
Info for the installer
Installation Guide | EN |
|| Surface Mounting Boxes ||
Deckhead Mounting Box - Art. 900939A -
- Deckhead Mounting Box with cable gland entries
- Protects bases from the ingress of water or other liquids
- Suitable for a variety of Apollo bases
STOCK KEEPING ARTICLE
Info for the installer
Installation Guide | EN |
Conduit Box - Art. 900933 -
- Surface mount box for lateral cable entry
- For use when detectors are installed on uneven surfaces
- Ensure correct fit
- Improves reliability
- Ensures that the mounting tags on the base are not over-tightened
STOCK KEEPING ARTICLE
|| Duct detector ||
XP95 Duct detector housing - Art. 085060 -
- Operates at airspeeds of 0.5m/s to 20m/s
- Standard sampling tube supplied for ducts up to 540mm
- Transparent cover to view detector LED
- Equipped with XP95 detector base
- Optional sampling tube lengths available for ducts up to 3000mm
STOCK KEEPING ARTICLE
Info for the installer
Installation Guide | EN |
|| Accessories ||
RAPID BRACKET®
- Mounting bracket for detector in inaccessible or hard to reach ceiling
- High quality durable materials
- Compatible with ceilings from 8mm to 32mm
- Designed for quick and easy installation
- Removes the need for access hatches
STOCK KEEPING ARTICLE
Info for the installer
Installation Guide | EN |
STI-9604 – Steel Web Stopper for fire detector - Art. 900005 -
- Protects the fire detector from vandalism and damage
- Made of sturdy galvanised steel with plastic coating
- Including mounting kit
- Colour : White
- Dimensions (H x W x D): 175 x 175 x 75mm
STOCK KEEPING ARTICLE